The new 375VA Victron Phoenix Inverter is an upgrade to the previous 250VA inverter. As standard, it now includes a number of additional features, such as teh VE.Direct port, making it far easier to communicate with the inverter.

VE.Direct communication port

The VE.Direct port can be connected to:

Fully configurable

Monitoring

In-and output voltage and current alarms

Proven reliability

The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature.

High start-up power

Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.

ECO mode

When in ECO mode, the inverter will switch to standby when the load decreases below a preset value. Once in standby the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.

Remote on/off

A remote on/off switch can be connected to a two pole connector, or between battery plus and the left hand contact of the two pole connector.

LED diagnosis

Please see manual for a description.

Automatic transfer switch

For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.

Available with different output sockets

Schuko UK (BS-1363) AU/NZ (3112) EC-320 (male plug included)

Screw terminals

No special tools needed for installation

Your item has been added to your basket

375VA Victron Phoenix Inverter UK (12/24/48V) with VE.Direct

£150.91

£125.76 ex. VAT

Technical Specification

12 Volt
12/250
12/375
12/500
24 Volt
24/250
24/375
24/500
48 Volt
48/375
48/500
Cont. power at 25°C
250VA
375VA
500VA
Cont. power at 25°C / 40°C
200 / 175W
300 / 260W
400/350W
Peak power
400W
700W
900W
Output AC voltage / frequency (adjustable)
230VAC +/- 3% 50Hz or 60Hz +/- 0,1%
Input voltage range
9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V
DC low shut down (adjustable)
9,3 / 18,6 / 37,2V
Dynamic (load dependent) DC low shut down (adjustable)
Dynamic cut-off
DC low restart and alarm (adjustable)
10,9 / 21,8 / 43,6V
Battery charged detect (adjustable)
14,0 / 28,0 / 56,0V
Max. efficiency
87 / 88 / 88%
89 / 89 / 90%
90 / 90%
Zero-load power
4,2 / 5,2 / 7,9W
5,6 / 6,1 / 8,5W
6 / 6,5W
Default zero-load power in ECO mode
0,8 / 1,3 / 2,5W
0,9 / 1,4 / 2,6W
1 / 1,5
ECO mode stop and start power setting >
Adjustable
Operating temperature range
-40 to +65°C (fan assisted cooling)
Humidity (non-condensing)
max 95%
ENCLOSURE
Material & Colour
Steel chassis and plastic cover  (blue Ral 5012)
Battery-connection
Screw terminals
Maximum cable cross-section
10 mm² / AWG8
10 mm² / AWG8
10 mm² / AWG8
Standard AC outlets
230V: Schuko (CEE 7/4), IEC-320 (male plug included) UK (BS 1363), AU/NZ (AS/NZS 3112) 120V: Nema 5-15R
Protection category
IP 21
Weight
2,4kg / 5,3lbs
3,0kg / 6,6lbs
3,9kg / 8.5lbs
Dimensions (hxwxd, mm)
86x165x260
86x165x260
86x172x275
ACCESSORIES
Remote on-off
Yes
Automatic transfer switch
Filax
STANDARDS
Safety
EN/IEC 60335-1 / EN/IEC 62109-1
EMC
EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-32004/104/EC
Automotive Directive
ECE R10-4
*All technical specifications and images are correct at the time of publication, but are subject to change without notice.
Your item has been added to your basket

375VA Victron Phoenix Inverter UK (12/24/48V) with VE.Direct

£150.91

£125.76 ex. VAT

Tell us about your project

Our Off-grid experts will come back with recommendations

x
Can we help?
Leading Edge
Off-Grid Power Requirements
Leading Edge
Sign Up To Receive Our Newsletter

Stay up to date with Leading Edge innovations and offers by joining our mailing list. Occassionally we send informative newsletters, offers and promotions that we think you'll find useful or interesting.